Dräger X-am 3500 Ex, O₂, CO LC, H₂S LC
with Inductive Charger (8325825) and Power Supply (8316997)

The Dräger X-am 3500 was especially designed for clearance measurements and personnel monitoring applications. The 1 to 4 gas detector reliably detects flammable gases and vapors as well as O2, CO, H2S, NO2 and SO2. The innovative signaling design and extensive range of accessories ensure optimum safety and easy handling.

Benefit 

  • Switch easily between pump and diffusion mode
  • Slots for Dräger Sensors to measure up to four gases
  • Measurement performance approval by external approval body (Europe):
    Flammable gases and vapours: methane, propane, n-nonane, oxygen as well as selected toxic gases
  • Glowing green D-Light (optional) indicates: tested and ready for use
  • Easy to read colour display with zoom function
  • Inductive charging


 Technical Data
Dimensions  (H x W x D) 179 x 77 x 42 mm
Weight Approx. 550 g, depending on sensor configuration, without strap, with pump
Housing Durable two component housing
Display High contrast colour display
Temperature 20 °C to + 50 °C
Pressure 700 to 1,300 hPa (measuring function)
800 to 1,100 hPa (use in explosion hazard areas)
Relative humidity 10 to 90 % (short-term up to 95 %) r.h.
 Alarm  Visual 3 LED 'red' (gas alarms),
3 LED 'yellow' (device alarms)

Acoustic Multitone, typically 100 dB(A) at 30 cm
 Ingress protection class  IP 68
Energy supply Lithium-ion battery, rechargeable, inductive charging
 Operating times (Diffusion) With CatEx and 3 EC-sensors  Typically 24 hours

With 3 EC-sensors  Typically 120 hours
 Charging times  Typically 4 hours after use during a shift of max.10 hours
Start up times  Typically <60 seconds for standard sensors
Data storage 24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the second on all 4 channels: approx. 600 hours
Pump operation Max. hose length 45 m


 

Dräger X-am 3500 Ex, O₂, CO LC, H₂S LC
with Inductive Charger (8325825) and Power Supply (8316997)

The Dräger X-am 3500 was especially designed for clearance measurements and personnel monitoring applications. The 1 to 4 gas detector reliably detects flammable gases and vapors as well as O2, CO, H2S, NO2 and SO2. The innovative signaling design and extensive range of accessories ensure optimum safety and easy handling.

Benefit 

  • Switch easily between pump and diffusion mode
  • Slots for Dräger Sensors to measure up to four gases
  • Measurement performance approval by external approval body (Europe):
    Flammable gases and vapours: methane, propane, n-nonane, oxygen as well as selected toxic gases
  • Glowing green D-Light (optional) indicates: tested and ready for use
  • Easy to read colour display with zoom function
  • Inductive charging


 Technical Data
Dimensions  (H x W x D) 179 x 77 x 42 mm
Weight Approx. 550 g, depending on sensor configuration, without strap, with pump
Housing Durable two component housing
Display High contrast colour display
Temperature 20 °C to + 50 °C
Pressure 700 to 1,300 hPa (measuring function)
800 to 1,100 hPa (use in explosion hazard areas)
Relative humidity 10 to 90 % (short-term up to 95 %) r.h.
 Alarm  Visual 3 LED 'red' (gas alarms),
3 LED 'yellow' (device alarms)

Acoustic Multitone, typically 100 dB(A) at 30 cm
 Ingress protection class  IP 68
Energy supply Lithium-ion battery, rechargeable, inductive charging
 Operating times (Diffusion) With CatEx and 3 EC-sensors  Typically 24 hours

With 3 EC-sensors  Typically 120 hours
 Charging times  Typically 4 hours after use during a shift of max.10 hours
Start up times  Typically <60 seconds for standard sensors
Data storage 24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the second on all 4 channels: approx. 600 hours
Pump operation Max. hose length 45 m