Dräger MT 1,3-Butadiene 0.5-25 ppm - PN 8610300
Dräger MT 1,3-Butadiene 0.5-25 ppm
PN : 8610300
Measuring Range |
0.5 to 25 ppm |
Typical Measuring Time |
10 to 280 s |
Accuracy | ± 15% ( under calibration conditions ) |
Ambient Conditions |
|
Temperature |
0 to 40 °C |
Humidity |
5 to 30 mg/L |
Cross Sensitivity |
No influence at 2 ppm 1.3 butadiene by: 5 ppm H2S 25 ppm white spirit 50 pm toluene 50 n-hexane 100 ppm benzene |
Hose and probe measurement |
The following flushing time recommendations for hose and probe measurement are marked with a brand-new , dry and clean hose and probes. |
Hose |
Length ( meter ) |
Flashing time (min) |
FKM hose |
5 - 20 |
3 |
FKM hose |
45 |
5 |
PTFE-line PVC hose |
3 - 15 | 3 |
Bar probe 90 (83 16 532) |
1 | |
Telescopic probe ES 150 ( 83 16 533) |
1 | |
Probe set GP600 )83 28 667) | 3 | |
Dräger MT 1,3-Butadiene 0.5-25 ppm
PN : 8610300
Measuring Range |
0.5 to 25 ppm |
Typical Measuring Time |
10 to 280 s |
Accuracy | ± 15% ( under calibration conditions ) |
Ambient Conditions |
|
Temperature |
0 to 40 °C |
Humidity |
5 to 30 mg/L |
Cross Sensitivity |
No influence at 2 ppm 1.3 butadiene by: 5 ppm H2S 25 ppm white spirit 50 pm toluene 50 n-hexane 100 ppm benzene |
Hose and probe measurement |
The following flushing time recommendations for hose and probe measurement are marked with a brand-new , dry and clean hose and probes. |
Hose |
Length ( meter ) |
Flashing time (min) |
FKM hose |
5 - 20 |
3 |
FKM hose |
45 |
5 |
PTFE-line PVC hose |
3 - 15 | 3 |
Bar probe 90 (83 16 532) |
1 | |
Telescopic probe ES 150 ( 83 16 533) |
1 | |
Probe set GP600 )83 28 667) | 3 | |