What is the Drager Tube® system?
DrägerTubes are glass vials filled with a chemical reagent that reacts to a specific chemical or family of chemicals. A calibrated 100 ml sample of air is drawn through the tube with the Dräger Accuro® bellows pump. If the targeted chemical(s) is present the reagent in the tube changes color and the length of the color change typically indicates the measured concentration. The Dräger Tubes System is the world's most popular form of gas detection.

Fast and reliable measuring
More than 200 different Dräger-tubes are available make spot measurements for over 500 gases and vapors.

Easy to use
The short-term Dräger tubes are employed manually together with the Dräger Accuro gas detection pump or automatically together with the pump Accuro 2000 or the compact microprocessor-controlled Quantimeter 1000.

Field applications
A great number of different gases and vapors can be measured by the short-term Dräger tubes. These tubes are used e.g. for the determination of concentration peaks, the measurement of exposures in the inhalation area, the determination of possible leakages as well as for the analysis of air in sewers, shafts, tanks or other confined spaces.



Application Range
Standard Measuring Range 1 to 25 ppm / 0.5 to 5 ppm
Number of Strokes n 10                / 20
Time for Measurement approx. 3 min  / approx. 6 min
Standard Deviation ± 10 to 15%
Color Change grey blue to white 
Ambient Operating Conditions
Temperature
10 to 30 °C
Absolute Humidity max 20 mg H2O/L 
 Cross Sensitivity
Measurement is not possible in the presence of H2S . Nitrogen dioxide will shorten the reading

Dräger-Tube Sulfur Dioxide 0.5/a (10)
PN: 6728491

Specifications
What is the Drager Tube® system?
DrägerTubes are glass vials filled with a chemical reagent that reacts to a specific chemical or family of chemicals. A calibrated 100 ml sample of air is drawn through the tube with the Dräger Accuro® bellows pump. If the targeted chemical(s) is present the reagent in the tube changes color and the length of the color change typically indicates the measured concentration. The Dräger Tubes System is the world's most popular form of gas detection.

Fast and reliable measuring
More than 200 different Dräger-tubes are available make spot measurements for over 500 gases and vapors.

Easy to use
The short-term Dräger tubes are employed manually together with the Dräger Accuro gas detection pump or automatically together with the pump Accuro 2000 or the compact microprocessor-controlled Quantimeter 1000.

Field applications
A great number of different gases and vapors can be measured by the short-term Dräger tubes. These tubes are used e.g. for the determination of concentration peaks, the measurement of exposures in the inhalation area, the determination of possible leakages as well as for the analysis of air in sewers, shafts, tanks or other confined spaces.



Application Range
Standard Measuring Range 1 to 25 ppm / 0.5 to 5 ppm
Number of Strokes n 10                / 20
Time for Measurement approx. 3 min  / approx. 6 min
Standard Deviation ± 10 to 15%
Color Change grey blue to white 
Ambient Operating Conditions
Temperature
10 to 30 °C
Absolute Humidity max 20 mg H2O/L 
 Cross Sensitivity
Measurement is not possible in the presence of H2S . Nitrogen dioxide will shorten the reading