Dräger-Tube Petroleum Hydrocarbons 10/a - PN: 8101691
Rated 3.5/5 based on 11 customer reviews

Dräger-Tube Petroleum Hydrocarbons 10/a - PN: 8101691

$113.00
Image

Dräger-Tube Petroleum Hydrocarbons 10/a (10)
PN: 8101691



Application Range
Standard Measuring Range 10 to 300 ppm for n-octane
Number of Strokes n 2
Time for Measurement approx. 1 min  
Standard Deviation ± 25%
Color Change white to brownish green 
Ambient Operating Conditions
Temperature
15 to 30 °C
Absolute Humidity 1 to 20 mg H2O/L 
 Cross Sensitivity
In addition to n-octane other organic or inorganic compounds are indicated as well.
50 ppm n-hexane indicates a discoloration of approx. 70 ppm
100 ppm n-heptane indicates a discoloration of  approx. 150 ppm
10 ppm iso-octane indicates a discoloration of  approx. 15 ppm
100 ppm is-octane indicates a discoloration of  approx. 150 ppm
200 ppm iso-octane indicates a discoloration of  approx. 350 ppm
50 ppm n-nonane indicates a discoloration of  approx. 50 ppm
50 ppm perchloreothylene a discoloration of  approx. 50 ppm
30 ppm CO indicates a discoloration of  approx. 20 ppm

Dräger-Tube Petroleum Hydrocarbons 10/a (10)
PN: 8101691



Application Range
Standard Measuring Range 10 to 300 ppm for n-octane
Number of Strokes n 2
Time for Measurement approx. 1 min  
Standard Deviation ± 25%
Color Change white to brownish green 
Ambient Operating Conditions
Temperature
15 to 30 °C
Absolute Humidity 1 to 20 mg H2O/L 
 Cross Sensitivity
In addition to n-octane other organic or inorganic compounds are indicated as well.
50 ppm n-hexane indicates a discoloration of approx. 70 ppm
100 ppm n-heptane indicates a discoloration of  approx. 150 ppm
10 ppm iso-octane indicates a discoloration of  approx. 15 ppm
100 ppm is-octane indicates a discoloration of  approx. 150 ppm
200 ppm iso-octane indicates a discoloration of  approx. 350 ppm
50 ppm n-nonane indicates a discoloration of  approx. 50 ppm
50 ppm perchloreothylene a discoloration of  approx. 50 ppm
30 ppm CO indicates a discoloration of  approx. 20 ppm