Dräger-Tube Hydrochloric Acid 1/a - PN: CH29501
Dräger-Tube Hydrochloric Acid 1/a - PN: CH29501
$113.00
Dräger-Tube Hydrochloric Acid 1/a (10 Tests per Box)
PN: CH29501
Application Range | |
Standard Measuring Range | 1 to 10 ppm |
Number of Strokes n | 10 |
Time for Measurement | approx. 2 min |
Standard Deviation | ± 10 to 15% |
Color Change | blue to yellow |
Ambient Operating Conditions | |
Temperature |
5 to 40 °C |
Absolute Humidity | max. 15 mg H2O/L |
Cross Sensitivity |
Hydrogen sulfide and sulfur dioxide in the TLV range do not interfere. It is impossible to measure hydrochloric acid in the presence of other mineral acids. Chlorine and nitrogen dioxide are indicated, but with different sensitivities. |
Dräger-Tube Hydrochloric Acid 1/a (10 Tests per Box)
PN: CH29501
Application Range | |
Standard Measuring Range | 1 to 10 ppm |
Number of Strokes n | 10 |
Time for Measurement | approx. 2 min |
Standard Deviation | ± 10 to 15% |
Color Change | blue to yellow |
Ambient Operating Conditions | |
Temperature |
5 to 40 °C |
Absolute Humidity | max. 15 mg H2O/L |
Cross Sensitivity |
Hydrogen sulfide and sulfur dioxide in the TLV range do not interfere. It is impossible to measure hydrochloric acid in the presence of other mineral acids. Chlorine and nitrogen dioxide are indicated, but with different sensitivities. |