Dräger Tube Hexane 10/a - PN: 8103681
Dräger Tube Hexane 10/a - PN: 8103681
$108.00
Dräger Tube Hexane 10/a (10)
PN: 8103681
Application Range:
- Standard Measuring Range: 10 to 200 ppm / 300 to 2500 ppm
- Number of Strokes n: 5 /1
- Time for Measurement: Approx. 75 sec / 5 sec
- Standard Deviation: ± 15 to 20 %
- Color Change: White → Brown Green
Ambient Operating Conditions:
- Temperature: 0 to 40 °C
- Absolute Humidity: 1 to 35 mg H2O / L
Reaction Principle:
- C5H12 + I2O5 → I2
Cross Sensitivity:
- Many petrol hydrocarbons also are indicated, however, all with different sensitivities.
- Differentiation is not possible.
- Aromatic hydrocarbons are only indicated with very low sensitivity.
- Carbon monoxide is indicated with slighlty lower sensitivity than n-hexane.